Areas of application |
|
Special characteristics |
|
Your benefit |
|
Tier 1 Fiber Certification for both Multimode and Singlemode Cabling in one Set
All-in-one fiber only encircled flux compliant tier 1 certifier for both multimode (850/1300 nm) and singlemode (1310/1550 nm) fiberoptic cabling. For multimode, EF compliance out of the box ensures measurement accuracies to highest industry standards. The included broadband power meter ranges from from 800 to 1650 nm.
The WireXpert MP range is packed with features that help saving time on the job. It is important to not only save a couple seconds per Autotest, but saving minutes completing all necessary steps for every link tested. If links fail, WireXpert MP translates complex RF measurements into easy-to-understand test results, helping users to pinpoint and repair issues. The devices are ergonomically optimized with 2 Autotest buttons for left- and right-handed use. Flip Tags allow the user to change the identity of the device of being either a local or remote unit making the device more flexible for various applications.
Advantages
Product details
Scope of delivery:
- 2 x Mainframe units
- 2 x Quad multimode and singlemode modules with SC and LC PC adaptors
- 2 x Headsets
- 1 Set Calibration and conformity certificates
- 1 Tri-Mode softcase
- 2 x Charging adapters
- 1 x Quick Start Guide
Note: Please order test reference cords separately
Accuracies:IEC 14763-3, IEC 61280-4-1, IEC 61280-4-2 |
Standard: ISO 11801, EN50173, TIA 568.3, JIS C5150, GB 50312 |
Input and output connectors: SC/PC, LC/PC, optional FC/PC, ST/PC |
LIGHT SOURCES |
Light Source: LED: 850 ±20 nm EF compliant, 1300 ±20 nm Fabry-Perot: 1310 ±20 nm 1550 ±20 nm |
Output TX power (nominal) at 23°C: MM: ≥-24 dBm, SM: ≥+4 dBm |
Output TX power stability: MM: ±0.05 dB over 8 hours, ±0.03 dB over 15 minutes SM: ±0.1 dB over 8 hours, ±0.08 dB over 15 minutes |
POWER METER |
Power Meter: 800 - 1650 nm, calibrated on 850, 1300, 1310, 1550 nm |
Power Measurement Range: 850 nm: 5dB m to -65 dBm, Others: 5 dBm to -70 dBm |
Power Measurement Uncertainty: ‹ ±5 % ±32 pW over 8 hours |
Measurement Linearity: ‹ ±0.1 dB over 8 hours |
Max Length: MM: 12 km, SM: 130 km |
Length measurement accuracy: ±1.5 m plus ±1 % of link length |
Units: dB, dBm, mW |
Full specifications see datasheet