The WireXpert 500 measurement solution for Industrial Ethernet cabling is suitable for measurementson LAN cabling with Industrial Ethernet connection technology. The Industrial Kit contains M12 D-coded and M12 X-coded interfaces, as well as RJ45 interfaces, which allow 10 Gigabit-capable Industrial Ethernet cabling to be measured efficiently.
Especially for applications in industrial data cabling, the kit includes, in addition to the WireXpert 500, adaptations for a variety of LAN cabling with Industrial Ethernet connection technology.
Advantages
Product details
WireXpert 500 Industrial
- 1 WireXpert 500 Local - with cover, without measuring adapter
- 1 WireXpert 500 Remote- with cover, without measuring adapter
- 2 power supplies
- 2 power cables
- 2 headphones
- 1 Envelope with calibration certificate, USB stick, quick start guide
- 2 Industrial adapters
- 2 TERA to preLink® measuring cables
- 1 TERA-TERA cable 2 m
- 2 preLink® M12 D socket
- 2 preLink® M12 X socket
- 2 preLink® M12 D plug
- 2 preLink® M12 X connector
- 2 preLink® RJ45 socket
- 2 preLink® RJ45 plug
- 1 Hard case
- 2 plastic sorting boxes for preLink® plugs and sockets
Parameters | Specification |
COPPER TESTING | |
Certification testing | TIA 568-D.2 Cat 5e, 6, 6A, Cat 8, 1005A, MPTL ISO/IEC 11801 series, |
Max cable length for dual-ended Autotest | 500m |
Insertion cycles | Channel: 10 000 typical, Permanent link: 5000 typical |
TEST PARAMETERS | As specified in TIA 1152A, IEC 61935 |
Wiremap | TIA 568A and 568B, crossover variants |
Loop Resistance | 0 to 40Ω, ±0.1Ω |
Length | 0 to 500m, ±0.5m (dual-ended testing) |
Propagation Delay and Delay Skew | 0 to 5000ns, ±1ns |
Attenuation | 0 to 70dB, ±0.1dB |
Pair-to-Pair and Power-Sum NEXT | 0 to 85dB, ±0.2dB |
Pair-to-Pair and Power-Sum ACRF | 0 to 85dB, ±0.2dB |
Return Loss | 0 to 40dB, ±0.2dB |
ACRN, PSACRN | 0 to 85 dB, ±0.5dB |
Advanced diagnostics | Time-domain fault Locator for RL and NEXT |
Measurement accuracy | Exceeds TIA 1152A Level IIIe, 2G and IEC 61935-1 Level IIIe, IV, V, VI |
Measurement frequency range | 1 - 500MHz |
GENERAL SPECIFICATIONS | |
Interfaces | Probe Interface, RJ45 Ethernet, USB host and device, talkset, power jack |
Display | 5" industrial LCD, touch sensitive area on both units |
Enclosure | Ruggedized plastic with rubber over-mold, withstands 1.5m drop test on hard surface |
Remote unit abilities | View test results, save tests, start autotest |
Power supply | AC 100-240V to 12V, 3A power adapter |
Input over-voltage protection | Protected against Telco voltages |
Battery | Removable and rechargeable Li-Ion |
Battery capacity | >8 hours continuous operation |
Internal storage capacity | 2000 copper test results with full plot information |
External storage | USB Flash Drive |
Dimensions | 232 x 126 x 87mm (8.7 x 4.3 x 2.1 inch) |
Weight | Approx. 1.4kg (3lb)/unit |
Supported languages | tw, cs, en, fi, fr, de, it, ja, ko, pl, pt, ru, es, sv, tr |
Calibration period | 1 year |
ENVIRONMENTAL | |
Operating temperature | 0 to 40°C |
Storage temperature | -20 to 60°C |
Relative humidity | 10% to 80% |
MINIMUM SYSTEM REQUIREMENTS FOR REPORTING SOFTWARE | |
Microsoft Windows 8/10, 32 or 64 bits | Intel Core i3, 2.4GHz and higher |
200MB of free disk space | 1GB RAM |
Microsoft.NET Framework 4.0 |