Copper cable certification up to Cat 6A and SPE cabling
WireXpert MP C6A, the full featured entry level product in the WireXpert MP range. The C6A module comes with all modern test options like DCRU and TCL and is software upgradable to 3000MHz. The C6A is the only Cat 6A certifier that is also capable of testing 600MHz SPE cabling. With its easy to use, intuitive user interface, this version is the perfect companion for installations in office and industrial environments. The WireXpert MP range is packed with features that help saving time on the job. It is important to not only save a couple seconds per Autotest, but saving minutes completing all necessary steps for every link tested. If links fail, WireXpert MP translates complex RF measurements into easy-to-understand test results, helping users to pinpoint and repair issues. The devices are ergonomically optimized with 2 Autotest buttons for left- and right-handed use. Flip Tags allow the user to change the identity of the device of being either a local or remote unit making the device more flexible for various applications.
WireXpert MP - Now with trade-in offer!
Advantages
Product details
Scope of delivery:
- 2x Mainframe units
- 2x Copper test module units
- 2x 6A channel test adapters
- 2x 6A permanent link test adapters
- 2x Cat 6A/Cat 8 long life cords
- 2x Charging adapters
- 2x Headsets (wired)
- 1x Quick Start Guide
- 1 Set calibration and conformity certificates
- 1x DCRU calibration artifact
- 1x Tri-Mode Softcase
COPPER TESTING |
Accuracies: Exceeds: IEC 61935-1 Level IIIe, IV; IEC 61935-1-1; IEC 61935-1-2; TIA 1152A Level IIIe; TIA-5071; draft ISO/IEC 61935-4 |
Max. cable length for dual-ended Autotest: Measurement range: 0 - 2000 m, display resolution: 0.1 m |
Insertion cycles: Channel: 10000 typical, Permanent link: 5000 typical |
TEST PARAMETERS |
Wiremap: TIA 568A and 568B, crossover variants, Profinet |
Loop Resistance: Measurement range: 0 - 200 Ohm, display resolution: 0.1 Ohm |
Length: Measurement range: 0 - 2000 m, display resolution: 0.1 m |
Propagation Delay and Delay Skew: Measurement range 1 ns – 10 μsec, display resolution: 1 ns |
RF Parameter Display Resolution: 0.1 dB |
Advanced diagnostics: Time-domain fault Locator for RL and NEXT |
Full specifications see datasheet