Areas of application |
|
Special characteristics |
|
Your benefit |
|
Copper cable certification up to Cat 8 and beyond
The C8 comes with all features of the C6A, but with a frequency range up to 3000MHz, making this product a future prove investment protection for use in office and datacenter environments. The C8 is capable of certifying Cat 8 links for 25 and 40Gbit/s Ethernet and more.
The WireXpert MP range is packed with features that help saving time on the job. It is important to not only save a couple seconds per Autotest, but saving minutes completing all necessary steps for every link tested. If links fail, WireXpert MP translates complex RF measurements into easy-to-understand test results, helping users to pinpoint and repair issues. The devices are ergonomically optimized with 2 Autotest buttons for left- and right-handed use. Flip Tags allow the user to change the identity of the device of being either a local or remote unit making the device more flexible for various applications.
WireXpert MP - Now with trade-in offer!
Advantages
Product details
Scope of delivery:
- 2x Mainframe kits
- 2x Copper test module units
- 2x Cat 8 channel test adapters
- 2x Cat 8 permanent link test adapters
- 2x Cat 8 long life cords
- 2x Charging adapters
- 2x Headsets (wired)
- 1x Quick Start Guide
- 1 Set calibration and conformity certificates
- 1x DCRU calibration artifact
- 1x Tri-Mode Softcase
COPPER TESTING |
Accuracies: Exceeds: IEC 61935-1 Level IIIe, IV, V, VI; IEC 61935-1-1; IEC 61935-1-2; TIA 1152A Level IIIe, 2G; TIA-5071; draft ISO/IEC 61935-4 |
Certification testing: TIA 568.2-E CAT 5e, 6, 6A, CAT 8, TIA 1005A, TIA 568.5, TIA 568.7; ISO/IEC 11801 series and EN 50173 Class D, E, EA, F, FA, Class I and Class II; TIA and ISO testing modes: Permanent link, channel, MPTL, E2E; Patchcord testing CAT 5e, 6, 6A, 7, 7A, 8 |
Max. cable length for dual-ended Autotest: Measurement range: 0 - 2000 m, display resolution: 0.1 m |
Insertion cycles: Channel:Channel: 10000 typical, Permanent link: 5000 typical |
TEST PARAMETERS |
Wiremap:TIA 568A and 568B, crossover variants, Profinet |
Loop Resistance:Measurement range: 0 - 200 Ohm, display resolution: 0.1 Ohm |
Length: Measurement range: 0 - 2000 m, display resolution: 0.1 m |
Propagation Delay and Delay Skew: Measurement range 1 ns – 10 μsec, display resolution: 1 ns |
RF Parameter Display Resolution: 0.1 dB |
Advanced diagnostics: Time-domain fault Locator for RL and NEXT |
Full specifications see datasheet