Follow the steps below:
1. Launch the eXport software
2. Select “Tools“ -> “Label List Generator“
The labeling scheme is based on the CENELEC EN 50173-1/ ISO/IEC 11801:2002 standard for structured cabling.
3. Determine the desired prefix in the field “Building“. The prefix remains unchanged in every label. Example: “Factory floor 1“ or “Company XY“
4. Now you have to decide which parts of the label you want to use. If, for example, there is only one floor and one telecommunications room these boxes can be unchecked. Then these parts will not be used.
5. Enter the required number in each part of the label. The first field contains the separator that separates the different parts of the label. Characters such as “Factory floor 1-1“ , “Factory floor 1|1“ , or “ Factory floor 1/1“ are commonly used. However, you can choose any character as you please.
6. Enter the start value. If you want to start with the first racks enter for example for example “1“ or “A“.
7. Enter the end value. If there are 3 racks in this building enter for example for example “3“ or “C“.
8. Enter a start and an end value for each label. The created labels will be displayed in the preview window below.
9. Insert a USB flash drive into the PC.
10. Select “Export to USB“ to copy the label list to the USB flash drive. Create a name for the list. It is useful to take the prefix.
11. Press “Export“ to copy the list. Insert the USB flash drive into the Local unit and copy the list to the WireXpert. Now, go to “Label“ to select the label list for the test.